Microinverter HM-400 1F Hoymiles

117  netto +VAT 23%

The world’s first single Daisy-Chain microinverter with an extremely wide range of DC input operating voltage (16-60 V) and low start-up voltage (only 22 V). System with an odd number of panels with CEC No. 1 weighted efficiency in the world – 96.5% (peak efficiency – 96.7%) in 2015. The microinverter complies with VDE-AR-N 4105: 2018 and EN50549-1: 2019.

The world’s first single Daisy-Chain microinverter with an extremely wide range of DC input operating voltage (16-60 V) and low start-up voltage (only 22 V). System with an odd number of panels with CEC No. 1 weighted efficiency in the world – 96.5% (peak efficiency – 96.7%) in 2015. The microinverter complies with VDE-AR-N 4105: 2018 and EN50549-1: 2019.

SKU: HOY HM-400
Category: Microinverter

Product description

The world’s first single Daisy-Chain microinverter with an extremely wide range of DC input operating voltage (16-60 V) and low start-up voltage (only 22 V). System with an odd number of panels with CEC No. 1 weighted efficiency in the world – 96.5% (peak efficiency – 96.7%) in 2015. The microinverter complies with VDE-AR-N 4105: 2018 and EN50549-1: 2019.

IMPORTANT: For each installation built with Hoymiles microinverters, a Hoymiles monitoring module must be selected. For this model, the choice is DTU-Pro or DTU-Lite.

Product distinguishing features:

  • Safer – Input voltage up to 60 V DC (natural fast shutdown) to guarantee no risk of electrocution and fire on the roof.
  • More powerful – MPPT at the module level to provide 10-30% more energy input from the sun compared to a string inverter.
  • Smaller, lighter and easier – Smaller than a sheet of A4 paper, only 1.98 kg with integrated AC cable (1 m), easy installation by one person.
  • More stable and reliable – Surge protection of 6000 V, MTBF (mean time between failures) >550 years, annual failure rate <0.18%.
  • Better return on cost (IRR) – Extremely low failure rate, longer life (starting voltage only 22 V), low LCOE (levelized cost of electricity) over a long period (more than 20 years) of investment.
  • Maximum efficiency of 96.7%
  • Input voltage range 16 to 60 V
  • Overvoltage protection of 6000 V
  • Ambient temperature range: -40 + 65 degrees C
  • External antenna to enhance communication with DTU
  • Adjustable power factor
  • Passive cooling, without fan
  • No typical inverter needed at the end of the chain

Operation and installation:

  • Easy assembly and disassembly
  • Mounting directly under the panel
  • Networking without the need for tools
  • Barcode stickers to identify devices in the installation
  • LED status indication on the housing
  • Communication via WiFi, 2.4 GHz range
  • Degree of protection IP67
  • Dimensions 164 x 182 x 29.5 mm

Usage:

  • Monitor the operation of each panel separately via the internet
  • Very low failure rate
  • High efficiency, minimal losses
  • Maximum safety, low DC input voltage
  • Noiseless operation
  • Standard warranty 12 years, extendable to 25 years

NOTE: Microinverter works only with panels whose maximum voltage (Voc) does not exceed 60 V.

Description

The world’s first single Daisy-Chain microinverter with an extremely wide range of DC input operating voltage (16-60 V) and low start-up voltage (only 22 V). System with an odd number of panels with CEC No. 1 weighted efficiency in the world – 96.5% (peak efficiency – 96.7%) in 2015. The microinverter complies with VDE-AR-N 4105: 2018 and EN50549-1: 2019.

IMPORTANT: For each installation built with Hoymiles microinverters, a Hoymiles monitoring module must be selected. For this model, the choice is DTU-Pro or DTU-Lite.

Product distinguishing features:

  • Safer – Input voltage up to 60 V DC (natural fast shutdown) to guarantee no risk of electrocution and fire on the roof.
  • More powerful – MPPT at the module level to provide 10-30% more energy input from the sun compared to a string inverter.
  • Smaller, lighter and easier – Smaller than a sheet of A4 paper, only 1.98 kg with integrated AC cable (1 m), easy installation by one person.
  • More stable and reliable – Surge protection of 6000 V, MTBF (mean time between failures) >550 years, annual failure rate <0.18%.
  • Better return on cost (IRR) – Extremely low failure rate, longer life (starting voltage only 22 V), low LCOE (levelized cost of electricity) over a long period (more than 20 years) of investment.
  • Maximum efficiency of 96.7%
  • Input voltage range 16 to 60 V
  • Overvoltage protection of 6000 V
  • Ambient temperature range: -40 + 65 degrees C
  • External antenna to enhance communication with DTU
  • Adjustable power factor
  • Passive cooling, without fan
  • No typical inverter needed at the end of the chain

Operation and installation:

  • Easy assembly and disassembly
  • Mounting directly under the panel
  • Networking without the need for tools
  • Barcode stickers to identify devices in the installation
  • LED status indication on the housing
  • Communication via WiFi, 2.4 GHz range
  • Degree of protection IP67
  • Dimensions 164 x 182 x 29.5 mm

Usage:

  • Monitor the operation of each panel separately via the internet
  • Very low failure rate
  • High efficiency, minimal losses
  • Maximum safety, low DC input voltage
  • Noiseless operation
  • Standard warranty 12 years, extendable to 25 years

NOTE: Microinverter works only with panels whose maximum voltage (Voc) does not exceed 60 V.

Share:
Facebook
Twitter
LinkedIn
Email